Industrial IoT Wireless CO2 Temperature Humidity Sensor Datasheet

Device Overview

NCD’s Long Range Industrial IoT Wireless CO2 Temperature Humidity Sensor offers air quality monitoring with an integrated temperature and humidity sensor, featuring up to a 2-mile range using wireless mesh networking. It transmits accurate CO2 concentration, temperature, and humidity data at user-defined intervals. CMOSens® technology provides precise CO2 measurements, while NDIR technology and a high-quality humidity and temperature sensor enhance accuracy.

The sensor compensates for long-term drifts using a dual-channel design, and its compact size allows easy integration. It operates from -25°C to 85°C and 0-90% RH, powered by 6 AA batteries with up to 5 years of life, depending on use. Its range, accuracy, and battery life make it a cost-effective solution for industrial and consumer applications.

Feature

  • Industrial Grade CO2 Measurement Range 400 – 5’000 ppm
  • CO2 Measurement Accuracy ± (60 ppm + 5% of reading)(25 °C, 400 – 5’000 ppm)
  • Repeatability 10 ppm and Temperature stability
  • NDIR measurement principle
  • Temperature compensation of CO2 sensor signal
  • Fully calibrated and linearized
  • Superior long-term stability With Built-in reference channel
  • Industrial Grade Sensor with 0 to 90% RH / -25°C [-13°F] to 85°C [185°F])
  • Resolution 0.4% RH/0.1°C Accuracy 6% RH/ 0.8°C
  • Includes Battery Level with Every Transmission
  • Validates and Retries Lost Communication Packets
  • Encrypted Wireless Communications up to 2 Mile Range
Figure 1: Device Overview

Status LED

The Status LED is used to indicate errors or other sensor diagnostics.

LED blinks once – Message was sent successfully and no error in last sensor read as well in data transmission.

LED blinks twice and then one more time – Message was sent successfully but there was an error in last sensor read.

LED blinks thrice – MCU is having issue communicating with the radio module.

Sensor Specifications

SpecificationsMinimumNominalMaximumNotes
Width3.54"
Length4.52"
Height2.16"
Enclosure RatingIP65, NEMA 1,2,4,4X,12,13, UL-508
Mounting 1/4 NPT
1/4-28 UNF
Magnet Mount
Temperature Rating-40° C23° C85° CComponent Rating
Tested Temperature0° C23° C40° CAs Tested by NCD Staff
Probe Temperature-40° C23° C105° CAs Tested by NCD Staff
Temperature range-25°C [-13°F]85°C [185°F]
Temperature resolution0.025°C
Temperature accuracy0.3°C
Relative Humidity range0 %100 %
Relative Humidity resolution0.04%
Relative Humidity accuracy2%
CO2 Measurement range400 ppm5000 ppm
CO2 Measurement accuracy60 ppm + 5% of reading
Mass Concentration range0 μg/m³1000 μg/m³
Mass Concentration resolution1 μg/m³
Mass Concentration precision ±10 %

Printed Circuit Board Specifications

ParameterMinimumNominalMaximumNotes
Trace Width0.007 inch0.012 inch0.25 inchTrace Width depends on the Trace Type
Layer Count2L - RigidTop and Bottom Layer
Material TypeFR-4 TG170FR-4 TG170FR-4 TG180
Surface FinishENIG 2u"
IPC StandardIPC CLASS 2
Finished Copper Foil1.0/1.0 OZ
Finished Thickness0.062 inc
Fine line <4.0/4.0milNo
Blind & Burried ViasNo
Non-Conductive ResinNo
Conductive ResinNo

Mechanical Drawing

Figure 3: Mechanical Drawing

RF Module Specifications

Parameter868MHz900MHz2.4GHz
Frequency Band863 MHz to 870 MHz902 to 928 MHzISM 2.4 GHz
Transmitter PowerUp to 13 dBm ERPUp to 24 dBmUp to 8 dBm
Receiver Sensitivity-106 dBm at 80 Kbps-101 dBm at 200 Kbps-103 dBm at 250 Kbps
Range (dense urban)~1000ft~1000ft~300ft
Range (line of sight)~2 miles~2 miles~1 mile
Data Rate80 Kbps200 Kbps250 Kbps
Networking ProtocolDigi XBee® DigiMesh®Digi XBee® DigiMesh®Digi XBee® DigiMesh®
Encryption128-bit AES128-bit AES128-bit
Reliable Packet DeliveryRetries/acknowledgementsRetries/acknowledgementsRetries/acknowledgements
IDsPAN ID and addresses, cluster IDs and endpoints (optional)PAN ID and addresses, cluster IDs and endpoints (optional)PAN ID and addresses, cluster IDs and endpoints (optional)
CertificationCE/RED, ROHS CompliantFCC (America), IC (Canada), C-Tick (Australia), Anatel (Brazil), IDA (Singapore)FCC (America), IC (Canada), RCM (Australia), Anatel (Brazil), Teleck MIC (Japan), KCC (South Korea)

Power Requirements and Expected Battery Life

Power Requirements

This Sensor is battery powered

Powered by AA batteries (NCD recommends Energizer L91 batteries).

While changing the batteries:

  1. Turn off the sensor
  2. Only use new L91 batteries
  3. Checkout the polarity marking on the battery holder and batteries
  4. Replace all six batteries with new L91 batteries. Do not mix old and new batteries
  5. Batteries should not be replaced in fire-risky areas
  6. Do NOT install rechargeable batteries

Expected Battery Life

SpecificationsMinimumNominalMaximumNotes
Batteries266May be Powered by 2 or 6 AA Batteries
Battery Life 1 TPD5 YearsTPD Transmissions per Day
Battery Life 12 TPD2 YearsTPD Transmissions per Day
Battery Life 24 TPD1 YearTPD Transmissions per Day