Industrial Wireless Absolute & Gauge Pressure Sensor With 1/4 NPT Datasheet

Device Overview

Introducing NCD’s IoT Industrial Wireless Absolute & Gauge Pressure and Temperature Sensor is the OEM piezo resistive pressure sensor with 316L stainless steel corrugated diaphragm and isolated oil-filling construction, boasting up to a 2 Mile range using a wireless mesh networking architecture. Incorporating a highly accurate Absolute & Gauge pressure sensor, transmits data at user-defined intervals. It measures Absolute & Gauge pressure and temperature with user configurable resolution at user defined intervals while sleeping during the time when it is not measuring or sending data.

Industrial Wireless Absolute & Gauge Pressure and Temperature Sensor is widely used for various liquid pressure measurement which is compatible with stainless steel and Viton®.  The included sensor is rated for 0-100psi absolute pressure, 0-500psi gauge pressure sensor, 0-1000psi sealed gauge sensor with an accuracy of ±0.5%FS (pressure),  and 0-5000psi sealed gauge sensor with an accuracy of ±0.5%FS (pressure)  ±1.5℃ (Temperature).  Easily interfaces using a standard 1/4″ NPT Male connection.

Features

  • Industrial Grade Sensor Long Range Wireless Pressure Temperature Sensor
  • Operating Range 0 to 10,000psi, -40°C to +85°C (-40°F to 185°F)
  • Industry Standard 1/4 inch NPT Male Connector
  • Accuracy ±0.5%FS (pressure)  ±1.5℃ (Temperature)
  • Sampling Frequency 1.5ms
  • Long Term Stability: ±0.3%FS/year
  • Compatible Media – Gas, Liquid or Vapor
  • 2 Mile Range with On-Board Antenna
  • Superior LOS Range of up to 28 miles with High-Gain Antennas
  • Wireless Mesh Networking using DigiMesh®
  • Open Communication Protocol for custom interfacing applications
  • Node-RED compatible – for configuration and displaying of data (NCD provided libraries)
  • IP65 Rated Enclosure
  • Improved reliability incorporating Retry feature in case of packet loss
  • Real Time Battery Status
Figure 1: Device Overview

Status LED

The Status LED is used to indicate errors or other sensor diagnostics.

LED blinks once – Message was sent successfully and no error in last sensor read as well in data transmission.

LED blinks twice and then one more time – Message was sent successfully but there was an error in last sensor read.

LED blinks thrice – MCU is having issue communicating with the radio module.

Sensor Specifications

SpecificationsMinimumNominalMaximumNotes
Width3.54"
Length4.52"
Height2.16"
Enclosure RatingIP65, NEMA 1,2,4,4X,12,13, UL-508
Temperature Rating-40° C23° C85° CComponent Rating
Tested Temperature0° C23° C40° CAs Tested by NCD Staff
Probe Temperature-40° C23° C85° CAs Tested by NCD Staff
Pressure range in PSI010 000Depending on the chosen probe when purchasing you range might be lower, we are listing the max here

Printed Circuit Board Specifications

ParameterMinimumNominalMaximumNotes
Trace Width0.007 inch0.012 inch0.25 inchTrace Width depends on the Trace Type
Layer Count2L - RigidTop and Bottom Layer
Material TypeFR-4 TG170FR-4 TG170FR-4 TG180
Surface FinishENIG 2u"
IPC StandardIPC CLASS 2
Finished Copper Foil1.0/1.0 OZ
Finished Thickness0.062 inc
Fine line <4.0/4.0milNo
Blind & Burried ViasNo
Non-Conductive ResinNo
Conductive ResinNo

Mechanical Drawing

Figure 3: Mechanical Drawing

RF Module Specifications

Parameter868MHz900MHz2.4GHz
Frequency Band863 MHz to 870 MHz902 to 928 MHzISM 2.4 GHz
Transmitter PowerUp to 13 dBm ERPUp to 24 dBmUp to 8 dBm
Receiver Sensitivity-106 dBm at 80 Kbps-101 dBm at 200 Kbps-103 dBm at 250 Kbps
Range (dense urban)~1000ft~1000ft~300ft
Range (line of sight)~2 miles~2 miles~1 mile
Data Rate80 Kbps200 Kbps250 Kbps
Networking ProtocolDigi XBee® DigiMesh®Digi XBee® DigiMesh®Digi XBee® DigiMesh®
Encryption128-bit AES128-bit AES128-bit
Reliable Packet DeliveryRetries/acknowledgementsRetries/acknowledgementsRetries/acknowledgements
IDsPAN ID and addresses, cluster IDs and endpoints (optional)PAN ID and addresses, cluster IDs and endpoints (optional)PAN ID and addresses, cluster IDs and endpoints (optional)
CertificationCE/RED, ROHS CompliantFCC (America), IC (Canada), C-Tick (Australia), Anatel (Brazil), IDA (Singapore)FCC (America), IC (Canada), RCM (Australia), Anatel (Brazil), Teleck MIC (Japan), KCC (South Korea)

Power Requirements and Expected Battery Life

Power Requirements

This Sensor has two power options:

  1. Powered by AA batteries (NCD recommends Energizer L91 batteries)
  2. External power supply (5-12 V DC) Current Requirement 250 mA

While changing the batteries:

  1. Turn off the sensor
  2. Only use new L91 batteries
  3. Checkout the polarity marking on the battery holder and batteries
  4. Replace all six batteries with new L91 batteries. Do not mix old and new batteries
  5. Batteries should not be replaced in fire-risky areas
  6. Do NOT install rechargeable batteries

Expected Battery Life

SpecificationsMinimumNominalMaximumNotes
Batteries266May be Powered by 2 or 4 AA Batteries
Battery Life 6 TPD10 YearsTPD Transmissions per Day
Battery Life 12 TPD8 YearsTPD Transmissions per Day
Battery Life 24 TPD6 YearTPD Transmissions per Day
Battery Life 96 TPD4 YearTPD Transmissions per Day
Store and Documentation

Head to the NCD store if you want to purchase the Absolute & Gauge Pressure Sensor.

If you already have the device and would like more information into its basic and advanced operations check out the Quick Start Guide and User Manual.