Commands Below are in Hex Format using API Mode. TX = Bytes Sent to the Controller RX = Bytes Received from the Controller.  Note Bytes Received May be Different for Some Commands.

C = Command
B = Bank
CK = Checksum (00-FF)
TX:23CBCKFunction:RX:23CK
AA03FE81002CTurn All Relays Off in All BanksAA015500
AA03FE81012DTurn All Relays Off in Bank 1AA015500
AA03FE81022ETurn All Relays Off in Bank 2AA015500
AA03FE81032FTurn All Relays Off in Bank 3AA015500
AA03FE810430Turn All Relays Off in Bank 4AA015500
AA03FE82002DTurn All Relays On in All BanksAA015500
AA03FE82012ETurn All Relays On in Bank 1AA015500
AA03FE82022FTurn All Relays On in Bank 2AA015500
AA03FE820330Turn All Relays On in Bank 3AA015500
AA03FE820431Turn All Relays On in Bank 4AA015500
AA03FE83002EInvert the Status of All Relays in All Relay BanksAA015500
AA03FE83012FInvert the Status of All Relays in Bank 1AA015500
AA03FE830230Invert the Status of All Relays in Bank 2AA015500
AA03FE830331Invert the Status of All Relays in Bank 3AA015500
AA03FE830432Invert the Status of All Relays in Bank 4AA015500
AA03FE84002FReverse the Pattern of All Relays in All Relay BanksAA015500
AA03FE840130Reverse the Pattern of All Relays in Bank 1AA015500
AA03FE840231Reverse the Pattern of All Relays in Bank 2AA015500
AA03FE840332Reverse the Pattern of All Relays in Bank 3AA015500
AA03FE840433Reverse the Pattern of All Relays in Bank 4AA015500