C1D2 Industrial IoT Wireless Structural Monitoring Sensor Datasheet

Device Overview

Primarily utilized for monitoring structural displacements, the C1D2 Industrial IoT Wireless Structural Monitoring Sensor detects movements and shifts at various structural points. Ideal for installation between footings and walls or alongside steel supports, this sensor reports any alterations in distance due to its spring-loaded cable mechanism. It is perfect for applications such as positional control, beam testing, hydraulic movement detection, and structural shift monitoring. The sensor is secured with two screws, plus an additional screw for the retractable cable, which provides analog position feedback during length changes.

Featuring a single-channel 10-bit ADC, the sensor periodically samples and wirelessly transmits data, entering a low-power sleep mode between transmissions to extend battery life. It can detect positional changes every 7 seconds (configurable), updating the cable length data if displacement varies by more than 10% (configurable). This energy-efficient operation, combined with a broad application spectrum, ensures its versatility. The sensor outputs an analog value from 0 to 1023, indicating full extension or retraction of the displacement cable.

The sensor uses a 50cm retractable wire cable, actively pulling to retract, and provides readings from 0 to 1023 as the cable extends. It should be mounted to track movements between two points, detecting linear shifts without assessing angular changes. Optimal functionality is achieved with the cable partially extended, allowing for precise detection of any length variation. However, it does not measure angular shifts, focusing solely on linear movements.

  • Wireless Structural Monitoring Sensor for Structural Monitoring
  • Industrial Grade IoT Displacement Sensor
  • 10-bit Resolution & Precision ±0.5% FS
  • Auto ADC Sample Transmission on Level Change
  • Configurable 10% Analog Voltage Change Detection
  • 2 Mile Line-of-Sight Range with On-Board Antenna
  • Interface with Popular Cloud Platforms:
    • Amazon® AWS®,  Microsoft® Azure®
    • Temboo, MQTT, Losant, Node-Red
  • Wireless Mesh Networking using DigiMesh®
  • Open Communication Protocol for Easy Software Integration
  • Includes Battery Level with Every Transmission
  • Validates and Retries Lost Communication Packets
Figure 1: Device Overview

Status LED

The Status LED is used to indicate errors or other sensor diagnostics.

LED blinks once – Message was sent successfully and no error in last sensor read as well in data transmission.

LED blinks twice and then one more time – Message was sent successfully but there was an error in last sensor read.

LED blinks thrice – MCU is having issue communicating with the radio module.

Sensor Specifications

SpecificationsMinimumNominalMaximumNotes
Width3.54"
Length4.52"
Height2.16"
Enclosure RatingIP65, NEMA 1,2,4,4X,12,13, UL-508
Mounting 1/4 NPT
1/4-28 UNF
Magnet Mount
Temperature Rating-40° C23° C85° CComponent Rating
Tested Temperature0° C23° C40° CAs Tested by NCD Staff

Printed Circuit Board Specifications

ParameterMinimumNominalMaximumNotes
Trace Width0.007 inch0.012 inch0.25 inchTrace Width depends on the Trace Type
Layer Count2L - RigidTop and Bottom Layer
Material TypeFR-4 TG170FR-4 TG170FR-4 TG180
Surface FinishENIG 2u"
IPC StandardIPC CLASS 2
Finished Copper Foil1.0/1.0 OZ
Finished Thickness0.062 inc
Fine line <4.0/4.0milNo
Blind & Burried ViasNo
Non-Conductive ResinNo
Conductive ResinNo

Mechanical Drawing

Figure 3: Mechanical Drawing

RF Module Specifications

Parameter868MHz900MHz2.4GHz
Frequency Band863 MHz to 870 MHz902 to 928 MHzISM 2.4 GHz
Transmitter PowerUp to 13 dBm ERPUp to 24 dBmUp to 8 dBm
Receiver Sensitivity-106 dBm at 80 Kbps-101 dBm at 200 Kbps-103 dBm at 250 Kbps
Range (dense urban)~1000ft~1000ft~300ft
Range (line of sight)~2 miles~2 miles~1 mile
Data Rate80 Kbps200 Kbps250 Kbps
Networking ProtocolDigi XBee® DigiMesh®Digi XBee® DigiMesh®Digi XBee® DigiMesh®
Encryption128-bit AES128-bit AES128-bit
Reliable Packet DeliveryRetries/acknowledgementsRetries/acknowledgementsRetries/acknowledgements
IDsPAN ID and addresses, cluster IDs and endpoints (optional)PAN ID and addresses, cluster IDs and endpoints (optional)PAN ID and addresses, cluster IDs and endpoints (optional)
CertificationCE/RED, ROHS CompliantFCC (America), IC (Canada), C-Tick (Australia), Anatel (Brazil), IDA (Singapore)FCC (America), IC (Canada), RCM (Australia), Anatel (Brazil), Teleck MIC (Japan), KCC (South Korea)

Power Requirements and Expected Battery Life

Power Requirements

This Sensor has two power options:

  1. Powered by AA batteries (NCD recommends Energizer L91 batteries)
  2. External power supply (5-12 V DC) Current Requirement 250 mA (optional)

While changing the batteries:

  1. Turn off the sensor
  2. Only use new L91 batteries
  3. Checkout the polarity marking on the battery holder and batteries
  4. Replace all six batteries with new L91 batteries. Do not mix old and new batteries
  5. Batteries should not be replaced in fire-risky areas
  6. Do NOT install rechargeable batteries

Expected Battery Life

SpecificationsMinimumNominalMaximumNotes
Batteries266May be Powered by 2 or 6 AA Batteries
Battery Life 1 TPD (TPD Transmissions per Day)10 YearsBattery estimation is based on a 30 min interval
Battery Life 12 TPD (TPD Transmissions per Day)8 YearsBattery estimation is based on a 30 min interval
Battery Life 24 TPD (TPD Transmissions per Day)5 YearBattery estimation is based on a 30 min interval
Battery Life 96 TPD (TPD Transmissions per Day)3 YearBattery estimation is based on a 30 min interval
Store and Documentation

Head to the NCD store if you want to purchase the C1D2 Industrial IoT Wireless Structural Monitoring Sensor.

If you already have the device and would like more information into its basic and advanced operations check out the Quick Start Guide and User Manual.