IoT Wireless Machine Run Time Hour Meter Datasheet

Explore the IoT Wireless Machine Run Time Hour Meter Capabilities

Device Overview

The IoT Wireless Machine Run Time Hour Meter is a device specifically designed to track machine and production run time in industrial settings. It is a flexible device that observes the behavior of the machine it is attached to via its built-in accelerometer and magnetometer.

It has long range wireless capabilities utilizing robust Mesh networking protocols with high level of security and network reliability. It is compact, durable and powered by long lasting batteries.

Features

  • Industrial Grade Machine Runtime Monitoring 
  • Measure Production Runtime
  • Measure Number of Cycles
  • Acceleration Motion Detection based Runtime calculator 
  • Magnetic Field Detection based Runtime calculator 
  • Encrypted Communication with 2 Mile Wireless Range
  • Operating Temperature Range -40 to +60 °C
  • Humidity Range 0-90%
  • Magnet Mounted IP67 Rated Enclosure
  • For Indoor and Outdoor Use
  • Many Gateway and Modem Options Available
Figure 1: Device Overview

Status LED

The Status LED is used to indicate errors or other sensor diagnostics.

LED blinks once – Message was sent successfully and no error in last sensor read as well in data transmission.

LED blinks twice and then one more time – Message was sent successfully but there was an error in last sensor read.

LED blinks thrice – MCU is having issue communicating with the radio module.

Sensor Specifications

SpecificationsMinimumNominalMaximumNotes
Height85mm
Base diameter48mm
Weight225g
Enclosure RatingIP67
Mounting ¼-28 UNF thread
Magnetic mount
Temperature Rating-40° C23° C70° CComponent Rating
Tested Temperature0° C23° C40° CAs Tested by NCD Staff
Accelerometer Sampling Rate25.6 kHzVibration Sensor Data Rate
Accelerometer Full-Scale Range-16g+16g
Accelerometer Noise70 μg/ √Hz
Magnetometer Bandwidth1000 Hz
Magnetometer Full-Scale Range-4, -8, -16 gauss+4, +8, +16 gauss
Magnetometer Noise6,842 LSB/gauss
Magnetometer Temperature CompensationEnabledEnsures reliable readings across varied conditions.
Sample Duration1sec1sec10secDevice will take readings for the set time and then send over wireless.
Max numbers 8100.

Printed Circuit Board Specifications

ParameterMinimumNominalMaximumNotes
Trace Width0.007 inch0.012 inch0.25 inchTrace Width depends on the Trace Type
Layer Count2L - RigidTop and Bottom Layer
Material TypeFR-4 TG170FR-4 TG170FR-4 TG180
Surface FinishENIG 2u"
IPC StandardIPC CLASS 2
Finished Copper Foil1.0/1.0 OZ
Finished Thickness0.062 inc
Fine line <4.0/4.0milNo
Blind & Burried ViasNo
Non-Conductive ResinNo
Conductive ResinNo

Mechanical Drawing

RF Module Specifications

Parameter868MHz900MHz2.4GHz
Frequency Band863 MHz to 870 MHz902 to 928 MHzISM 2.4 GHz
Transmitter PowerUp to 13 dBm ERPUp to 24 dBmUp to 8 dBm
Receiver Sensitivity-106 dBm at 80 Kbps-101 dBm at 200 Kbps-103 dBm at 250 Kbps
Range (dense urban)~1000ft~1000ft~300ft
Range (line of sight)~2 miles~2 miles~1 mile
Data Rate80 Kbps200 Kbps250 Kbps
Networking ProtocolDigi XBee® DigiMesh®Digi XBee® DigiMesh®Digi XBee® DigiMesh®
Encryption128-bit AES128-bit AES128-bit
Reliable Packet DeliveryRetries/acknowledgementsRetries/acknowledgementsRetries/acknowledgements
IDsPAN ID and addresses, cluster IDs and endpoints (optional)PAN ID and addresses, cluster IDs and endpoints (optional)PAN ID and addresses, cluster IDs and endpoints (optional)
CertificationCE/RED, ROHS CompliantFCC (America), IC (Canada), C-Tick (Australia), Anatel (Brazil), IDA (Singapore)FCC (America), IC (Canada), RCM (Australia), Anatel (Brazil), Teleck MIC (Japan), KCC (South Korea)

Power Requirements and Expected Battery Life

Power Requirements

  1. This device is Powered by a single D-cell (LR20) battery

While changing the batteries:

  1. Turn off the sensor
  2. Only use a new D-cell battery (obtain one from NCD, as it has a built in supercapacitor, this is not a regular battery).
  3. Make sure to align the connector in the proper orientation (this will assure you match the polarity)
  4. The battery should not be replaced in fire-risky areas
  5. Do NOT install a rechargeable battery

Expected Battery Life

SpecificationsMinimumNominalMaximumNotes
Batteries size16000mAhThis device has a single D-Cell (LR20) battery
Battery Life 1 TPD10 YearsTPD Transmissions per Day
Battery Life 12 TPD8 YearsTPD Transmissions per Day
Battery Life 24 TPD5 YearTPD Transmissions per Day
Battery Life 96 TPD3 YearTPD Transmissions per Day
Store and Documentation

Head to the NCD store if you want to purchase the IoT Wireless Machine Run Time Hour Meter.

If you already have the device and would like more information into its basic and advanced operations check out the Quick Start Guide and User Manual.