Relay Timers and Flashers are directly connected, meaning Relay Timer 1 is directly connected to Flasher 1. Similarly, Timer 2 is connected to Flasher 2. This makes it possible to flash a relay for a period of time using a pair of commands. The following commands demonstrate Flash Timer features working together.
Start by turning on Flasher 1:
CK = Checksum (00-FF)TX: | 2 | 3 | 4 | 5 | 6 | CK | Function: | RX: | 2 | 3 | CK |
---|---|---|---|---|---|---|---|---|---|---|---|
AA | 04 | FE | 2D | 01 | 01 | DB | Step 1: Turn On Flasher 1 | AA | 01 | 55 | 00 |
Next, Activate Timer 1:
CK = Checksum (00-FF)TX: | 2 | 3 | 4 | 5 | 6 | 7 | 8 | CK | Function: | RX: | 2 | 3 | CK |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
AA | 06 | FE | 32 | 32 | 00 | 00 | 0A | 1C | Activate Timer 1 | AA | 01 | 55 | 00 |
When the timer expires, the relay flasher will be canceled. Note that all 16 timers are connected to all 16 flashers in this same way.