Commands Below are in Hex Format using API Mode. TX = Bytes Sent to the Controller RX = Bytes Received from the Controller. Note Bytes Received May be Different for Some Commands.
C = CommandB = Bank
CK = Checksum (00-FF)
TX: | 2 | 3 | C | B | CK | Function: | RX: | 2 | 3 | CK |
---|---|---|---|---|---|---|---|---|---|---|
AA | 03 | FE | 81 | 00 | 2C | Turn All Relays Off in All Banks | AA | 01 | 55 | 00 |
AA | 03 | FE | 81 | 01 | 2D | Turn All Relays Off in Bank 1 | AA | 01 | 55 | 00 |
AA | 03 | FE | 81 | 02 | 2E | Turn All Relays Off in Bank 2 | AA | 01 | 55 | 00 |
AA | 03 | FE | 81 | 03 | 2F | Turn All Relays Off in Bank 3 | AA | 01 | 55 | 00 |
AA | 03 | FE | 81 | 04 | 30 | Turn All Relays Off in Bank 4 | AA | 01 | 55 | 00 |
AA | 03 | FE | 82 | 00 | 2D | Turn All Relays On in All Banks | AA | 01 | 55 | 00 |
AA | 03 | FE | 82 | 01 | 2E | Turn All Relays On in Bank 1 | AA | 01 | 55 | 00 |
AA | 03 | FE | 82 | 02 | 2F | Turn All Relays On in Bank 2 | AA | 01 | 55 | 00 |
AA | 03 | FE | 82 | 03 | 30 | Turn All Relays On in Bank 3 | AA | 01 | 55 | 00 |
AA | 03 | FE | 82 | 04 | 31 | Turn All Relays On in Bank 4 | AA | 01 | 55 | 00 |
AA | 03 | FE | 83 | 00 | 2E | Invert the Status of All Relays in All Relay Banks | AA | 01 | 55 | 00 |
AA | 03 | FE | 83 | 01 | 2F | Invert the Status of All Relays in Bank 1 | AA | 01 | 55 | 00 |
AA | 03 | FE | 83 | 02 | 30 | Invert the Status of All Relays in Bank 2 | AA | 01 | 55 | 00 |
AA | 03 | FE | 83 | 03 | 31 | Invert the Status of All Relays in Bank 3 | AA | 01 | 55 | 00 |
AA | 03 | FE | 83 | 04 | 32 | Invert the Status of All Relays in Bank 4 | AA | 01 | 55 | 00 |
AA | 03 | FE | 84 | 00 | 2F | Reverse the Pattern of All Relays in All Relay Banks | AA | 01 | 55 | 00 |
AA | 03 | FE | 84 | 01 | 30 | Reverse the Pattern of All Relays in Bank 1 | AA | 01 | 55 | 00 |
AA | 03 | FE | 84 | 02 | 31 | Reverse the Pattern of All Relays in Bank 2 | AA | 01 | 55 | 00 |
AA | 03 | FE | 84 | 03 | 32 | Reverse the Pattern of All Relays in Bank 3 | AA | 01 | 55 | 00 |
AA | 03 | FE | 84 | 04 | 33 | Reverse the Pattern of All Relays in Bank 4 | AA | 01 | 55 | 00 |