Commands Below are in Hex Format using API Mode. TX = Bytes Sent to the Controller RX = Bytes Received from the Controller. Note Bytes Received May be Different for Some Commands.
R = RelayB = Bank
CK = Checksum
TX: | 2 | 3 | R | B | CK | Function: | RX: | 2 | 3 | CK |
---|---|---|---|---|---|---|---|---|---|---|
AA | 03 | FE | 6C | 01 | 18 | Turn On Relay 1 in Bank 1 | AA | 01 | 55 | 00 |
AA | 03 | FE | 6D | 01 | 19 | Turn On Relay 2 in Bank 1 | AA | 01 | 55 | 00 |
AA | 03 | FE | 6E | 01 | 1A | Turn On Relay 3 in Bank 1 | AA | 01 | 55 | 00 |
AA | 03 | FE | 6F | 01 | 1B | Turn On Relay 4 in Bank 1 | AA | 01 | 55 | 00 |
AA | 03 | FE | 70 | 01 | 1C | Turn On Relay 5 in Bank 1 | AA | 01 | 55 | 00 |
AA | 03 | FE | 71 | 01 | 1D | Turn On Relay 6 in Bank 1 | AA | 01 | 55 | 00 |
AA | 03 | FE | 72 | 01 | 1E | Turn On Relay 7 in Bank 1 | AA | 01 | 55 | 00 |
AA | 03 | FE | 73 | 01 | 1F | Turn On Relay 8 in Bank 1 | AA | 01 | 55 | 00 |
AA | 03 | FE | 6C | 02 | 19 | Turn On Relay 1 in Bank 2 | AA | 01 | 55 | 00 |
AA | 03 | FE | 6C | 03 | 1A | Turn On Relay 1 in Bank 3 | AA | 01 | 55 | 00 |
AA | 03 | FE | 6C | 04 | 1B | Turn On Relay 1 in Bank 4 | AA | 01 | 55 | 00 |