Device Overview
NCD IoT Wireless AC Current Detection sensor transmitters makes it easy to receive alerts when the AC current value exceeds the preset limits. This current limit can be set up via an on-board Potentiometer. This IoT long range wireless AC Current Detection sensor transmitter includes one 0-100Amp AC current clamp, that is used to detect if there is any current flowing through the sensor. The input current range is 0-100A, sending a transmission if the measured value is over the set threshold. The sensor also sends packets periodically, indicating the input status as well as the battery level, just to let you know it’s alive and well.
Receive an alert when AC current value exceeds the preset value, receive another alert when the AC current drops below preset value. This IoT long range wireless AC Current Detection sensor is ideally used in Automation applications that need a reliable long-range wireless AC current detect transmission. Powered by two AA batteries, it has up to 10 years of battery life depending on environmental conditions and the transmission interval required for your application. Optionally, this sensor may be externally powered.
This AC Current Detection sensor transmitter will send wireless push notifications over a distance of up to 2 miles using the included antennas (line of sight) or up to 28 miles using high-gain antennas.
Feature
- Industrial Long Range Wireless AC Current Detection Sensor
- Selectable Current Sensor:
- 100 amp CT
- 200 amp CT
- 600 amp CT
- 1000 amp CT
- 2 Mile Line-of-Sight Range with On-Board Antenna
- Superior LOS Range of up to 28 Miles with High-Gain Antennas
- Easy configuration and management via an open Node-RED library
- Wireless Mesh Networking using DigiMesh®
- Open Communication Protocol for Easy Software Integration
- Power-Efficient Sleep Mode, Up to 10 Year Battery Life – User Configurable Sleep duration
- Includes Battery Level with Every Transmission
- Validates and Retries Lost Communication Packets
Status LED
The Status LED is used to indicate errors or other sensor diagnostics.
LED blinks once – Message was sent successfully and no error in last sensor read as well in data transmission.
LED blinks twice and then one more time – Message was sent successfully but there was an error in last sensor read.
LED blinks thrice – MCU is having issue communicating with the radio module.
Sensor Specifications
Specifications | Minimum | Nominal | Maximum | Notes |
---|---|---|---|---|
Width | 3.54" | |||
Length | 4.52" | |||
Height | 2.16" | |||
Enclosure Rating | IP65, NEMA 1,2,4,4X,12,13, UL-508 | |||
Mounting | 1/4 NPT 1/4-28 UNF Magnet Mount | |||
Temperature Rating | -40° C | 23° C | 85° C | Component Rating |
Tested Temperature | 0° C | 23° C | 40° C | As Tested by NCD Staff |
Probe Temperature | -40° C | 23° C | 105° C | As Tested by NCD Staff |
Temperature range | -25°C [-13°F] | 85°C [185°F] | ||
Current probe specs [Max current range / Resolution / Minimum detectable current | 100A / 50mA / 2A | |||
200A / 100mA / 4A | ||||
600A / 300mA / 12A | ||||
1000A / 500mA / 20A |
Printed Circuit Board Specifications
Parameter | Minimum | Nominal | Maximum | Notes |
---|---|---|---|---|
Trace Width | 0.007 inch | 0.012 inch | 0.25 inch | Trace Width depends on the Trace Type |
Layer Count | 2L - Rigid | Top and Bottom Layer | ||
Material Type | FR-4 TG170 | FR-4 TG170 | FR-4 TG180 | |
Surface Finish | ENIG 2u" | |||
IPC Standard | IPC CLASS 2 | |||
Finished Copper Foil | 1.0/1.0 OZ | |||
Finished Thickness | 0.062 inc | |||
Fine line <4.0/4.0mil | No | |||
Blind & Burried Vias | No | |||
Non-Conductive Resin | No | |||
Conductive Resin | No |
Mechanical Drawing
RF Module Specifications
Parameter | 868MHz | 900MHz | 2.4GHz |
---|---|---|---|
Frequency Band | 863 MHz to 870 MHz | 902 to 928 MHz | ISM 2.4 GHz |
Transmitter Power | Up to 13 dBm ERP | Up to 24 dBm | Up to 8 dBm |
Receiver Sensitivity | -106 dBm at 80 Kbps | -101 dBm at 200 Kbps | -103 dBm at 250 Kbps |
Range (dense urban) | ~1000ft | ~1000ft | ~300ft |
Range (line of sight) | ~2 miles | ~2 miles | ~1 mile |
Data Rate | 80 Kbps | 200 Kbps | 250 Kbps |
Networking Protocol | Digi XBee® DigiMesh® | Digi XBee® DigiMesh® | Digi XBee® DigiMesh® |
Encryption | 128-bit AES | 128-bit AES | 128-bit |
Reliable Packet Delivery | Retries/acknowledgements | Retries/acknowledgements | Retries/acknowledgements |
IDs | PAN ID and addresses, cluster IDs and endpoints (optional) | PAN ID and addresses, cluster IDs and endpoints (optional) | PAN ID and addresses, cluster IDs and endpoints (optional) |
Certification | CE/RED, ROHS Compliant | FCC (America), IC (Canada), C-Tick (Australia), Anatel (Brazil), IDA (Singapore) | FCC (America), IC (Canada), RCM (Australia), Anatel (Brazil), Teleck MIC (Japan), KCC (South Korea) |
Power Requirements and Expected Battery Life
Power Requirements
This Sensor is battery powered
Powered by AA batteries (NCD recommends Energizer L91 batteries).
Can also be powered by an External Power supply.
While changing the batteries:
- Turn off the sensor
- Only use new L91 batteries
- Checkout the polarity marking on the battery holder and batteries
- Replace all six batteries with new L91 batteries. Do not mix old and new batteries
- Batteries should not be replaced in fire-risky areas
- Do NOT install rechargeable batteries
Expected Battery Life
Specifications | Minimum | Nominal | Maximum | Notes |
---|---|---|---|---|
Batteries | 2 | 6 | 6 | May be Powered by 2 or 6 AA Batteries |
Battery Life 1 TPD | 10 Years | TPD Transmissions per Day | ||
Battery Life 12 TPD | 8 Years | TPD Transmissions per Day | ||
Battery Life 24 TPD | 5 Year | TPD Transmissions per Day | ||
Battery Life 96 TPD | 3 Year | TPD Transmissions per Day |