Tag: LabView

Installing LabVIEW USB RS232 RS485 Relay Controller Instrument Driver

Installing LabVIEW USB RS232 RS485 Relay Controller Instrument Driver This Guide contains instructions for Installing LabVIEW USB RS232 RS485 Relay Controller Instrument Driver on your development environment. Please go through the following Steps to Install this driver: Download Instrument driver ZIP file from ProXR-labview-driver-v3 Extract this file and Copy ProXR folder. Paste this Folder in the instr.lib folder in your LabVIEW installation folder. Download Instrument driver 2011 ZIP file from ProXR-labview-driver-v3.2.rar_ If you are looking for USB, RS485, RS232 relay controller exe you can find it over here Ncdio-ProXR-Relay-Tester-v2.0.0.rar_ Example: For LabVIEW 2015 32-bit installation on a 64-bit Windows environment, paste

Read More »

Labview Relay switching and Status acquisition 1

LabVIEW Relay switching and Status acquisition 1 In this LabVIEW relay switching article we will learn how to on off a relay, how to check relay status, bank status. These LabVIEW relay drivers will work with most of the ncd.io industrial relay controllers. which can be found over here Industrial Relay Controller For labview A) Setting a Relay ON/OFF and getting Status in Current Bank This guide shows how to turn a relay ON take status, then wait 5 seconds, turn it OFF and again take status. This VI handles relay in current bank which is set with another command.

Read More »

LabVIEW Relay Controller Advanced Configuration

LabVIEW Relay Controller Advanced Configuration In this LabVIEW Relay Controller Advanced Configuration guide we will learn how to set relay delay, read delay, set, read relay bank values and relay test bench. A) Set and Read Character Delay Value This guide illustrates how to set and read character delay value Related Example in Driver: Character Delay Configuration.vi VIs Required: –> Initialize (Main Palette) –> Set Character Delay (Configuration->Advanced Palette) –> Read Character Delay (Configuration->Advanced  Palette) –> Close (Main Palette) Following figure shows the steps for this guide. Their detail follows the figure. Details of steps is as under. Port is

Read More »

LabVIEW Relay controller Basic Configuration

LabVIEW Relay controller Basic Configuration In this LabVIEW Relay controller Basic Configuration manual we will learn how to automatically and manually refresh the relays, how to set and relay relay bank, set and read default relay state. A) Automatic vs Manual Refresh This example illustrates how to Disable Automatic refreshing and refresh Relays Manually. Related Example in Driver: Relay Refreshing.vi It works as follows, Turns OFF automatic refreshing Reads back Refreshing Status to verify. Turns on Relay 2 and 3 in Bank 1, then waits 5 seconds Manually Refreshes Relays, again waits 5 seconds Turns on Automatic Relay Refreshing Turns

Read More »

LabVIEW Relay switching and Status acquisition 2

LabVIEW Relay switching and Status acquisition 2 In this LabVIEW Relay switching article we will learn how read relay status, set relay status and relay grouping. These LabVIEW relay drivers will work with most of the ncd.io industrial relay controllers. which can be found over here Industrial Relay Controller For labview A) Read Relay Status for 8 Relays This guide shows how to read status of all 8 relays in currently selected relay bank. Related Example in Driver: Read Relay Status 8 Relays.vi VIs Required: –> Initialize (Main Palette) –> Read Relay Status 8 Relays (Action Status->Advanced Palette) –> Close

Read More »

LabVIEW Relay Timer Operation

LabVIEW Relay Timer Operation In This Guide we will learn how to setup LabVIEW Relay Timer Operation, Pulse activated relay board and fixed time schedule relay. A) Timer Calibration This guide illustrates how to set Calibrate a timer and read back its calibration value. Related Example in Driver: Timer Calibration.vi VIs Required: –> Initialize (Main Palette) –> Calibrate (Timers Palette) –> Read Calibration (Timers Palette) –> Close (Main Palette) Following figure shows the steps for this guide. Their detail follows the figure. Details of steps is as under. Port is initialized in Initialize VI with fixed baud rate of 115200.

Read More »