Category: Post Type

Wireless IoT ORP pH and Temperature Sensor Product Manual

NCD’s Long Range Industrial IoT Wireless pH ORP Temperature SensorFeaturesApplicationsDescriptionGetting StartedResources RequiredStepsTroubleshootingChanged/Unknown setting at sensor endChanged/Unknown setting at PC endModes of OperationMode Selection ProcessFrame Communication at Power upRun ModeConfiguration ModeAppendix AConfiguration Commands1. Set Broadcast Transmission2. Set ID and Delay3. Set Destination Address4. Set Power5. Set PANID6. Set Retries7. Read Delay8. Read Power9. Read Retries10. Read Destination Address11. Read PANID12. Enable Encryption13. Disable Encryption14. Set Encryption Key15. Sensor pH Calibration16. Set pH Probe Warm up time17. Set Temperature17. Enable Disable Temperature Compensation18. On Demand Data19. Super Command20. Sensor ORP CalibrationAppendix BFrame Checksum CalculationNCD’s Long Range Industrial IoT Wireless pH ORP Temperature

Read More »

Industrial IoT Wireless Tilt and Inclinometer Sensor Product Manual

Features Industrial Grade Tilt Sensor with Roll and Pitch Detection Configurable Roll and Pitch Angle Parameters Uses Interrupts for Tilt detection with little power consumption Measuring range: Roll: ±90°, Pitch: ±90° Angle detection resolution ±0.5° for high precision application Operating Temperature Range -40 to +85 °C Superior LOS Range of up to 28 miles with 900MHz High-Gain Antennas Interface to Raspberry Pi, Microsoft Azure, Arduino and More Example Software for Visual Studio and LabVIEW Wireless Mesh Networking using DigiMesh® 256 Sensor Node per Network Open Communication Protocol for custom interfacing applications Small Form Factor Wireless Sensor (3×3 inch) Two modes

Read More »

IoT Ultrasonic Proximity Sensor For Tank Level Monitoring Product Manual

OverviewFeaturesApplicationsDescriptionGetting StartedResources RequiredStepsTroubleshootingChanged/Unknown setting at sensor endChanged/Unknown setting at PC endModes of OperationMode Selection ProcessFrame Communication at Power upRun ModeConfiguration ModeAppendix AConfiguration Commands1. Set Broadcast Transmission2. Set ID and Delay3. Set Destination Address4. Set Power5. Set PANID6. Set Retries7. Read Delay8. Read Power9. Read Retries10. Read Destination Address11. Read PANID12. Enable Encryption13. Disable Encryption14. Set Encryption Key15. Set Sensor Change Detection Parameter16. Read Sensor Change Detection ParameterAppendix BFrame Checksum CalculationOverview Features Industrial Grade Ultrasonic Tank Level Sensor Reading-to-reading stability of 1-mm at 1-meter is typical Sensor features 1-mm resolution Target size compensation provides greater consistency and accuracy Detection Range upto

Read More »

IoT CO2 Temperature Humidity Sensor for Air Quality Monitoring Product Manual

OverviewFeaturesApplicationsDescriptionGetting StartedResources RequiredStepsTroubleshootingChanged/Unknown setting at sensor endChanged/Unknown setting at PC endModes of OperationMode Selection ProcessFrame Communication at Power upRun ModeConfiguration ModeAppendix AConfiguration Commands1. Set Broadcast Transmission2. Set ID and Delay3. Set Destination Address4. Set Power5. Set PANID6. Set Retries7. Read Delay8. Read Power9. Read Retries10. Read Destination Address11. Read PANID12. Enable Encryption13. Disable Encryption14. Set Encryption Key14. Set Sensor Temperature Offset Coefficient15. Set Sensor Altitude Value16. Set Sensor Forced Calibration ValueAppendix BFrame Checksum CalculationOverview Features Industrial Grade CO2 Measurement Range 0 – 40’000 ppm CO2 Measurement Accuracy ± (30 ppm + 3% MV)(25 °C, 400 – 10’000 ppm) Repeatability 10 ppm And

Read More »

Industrial IoT Wireless High Resolution 4-20mA Receiver Product Manual

Features Industrial Grade 1 Channel 16 bit ADC 4-20mA Reveiver 15 bit 4-20mA Resolution ±0.68uA Absolute Accuracy Auto ADC sample transmission or on analog voltage change detection periodically (configurable duration in both cases) Configurable Analog voltage change detection percentage 1-Mile Range with 2.4GHz or 2 Mile Range with 900MHz On-Board Antenna Superior LOS Range of up to 28 miles with 900MHz High-Gain Antennas Interface to Raspberry Pi, Microsoft Azure, Arduino and More Example Software for Visual Studio and LabVIEW Wireless Mesh Networking using DigiMesh® Open Communication Protocol for custom interfacing applications Configuration mode for Sensor and X-bee Settings Factory Default

Read More »

IoT Wireless Temperature Humidity Current Detect Sensor Product Manual

Overview Features Two Industrial Grade Sensor  Probes with Range 0 to 100% RH / -25°C [-13°F] to 85°C [185°F]) 0-100Amp AC Current Detection Sensor Resolution 0.01% RH/0.01°C Accuracy 2% RH/ 0.2°C 2 Mile Range with On-Board Antenna Superior LOS Range of up to 28 miles with High-Gain Antennas Interface to Raspberry Pi, Microsoft Azure, Arduino and More Example Software for Visual Studio and LabVIEW Wireless Mesh Networking using DigiMesh® 256 Sensor Node per Network Open Communication Protocol for custom interfacing applications Improved reliability incorporating Retry feature in case of packet loss Real time battery status Applications In House Temperature Humidity

Read More »

IoT Wireless TVOC CO2eq Temperature Humidity Sensor Product Manual

OverviewFeaturesApplicationsDescriptionGetting StartedResources RequiredStepsTroubleshootingChanged/Unknown setting at sensor endChanged/Unknown setting at PC endModes of OperationMode Selection ProcessFrame Communication at Power upRun ModeConfiguration ModeAppendix AConfiguration Commands1. Set Broadcast Transmission2. Set ID and Delay3. Set Destination Address4. Set Power5. Set PANID6. Set Retries7. Read Delay8. Read Power9. Read Retries10. Read Destination Address11. Read PANID12. Enable Encryption13. Disable Encryption14. Set Encryption Key15. Force Sensor CleanAppendix BFrame Checksum CalculationOverview Features Industrial Grade Gas and Temperature Humidity Sensor High Resolution TVOC and CO2eq output TVOC output range 0 to 60,000 ppb CO2eq Output range 400 to 60,000 ppm Low long term drift ( 1.3% of measurement value)

Read More »

IoT Wireless AC Current Detection Push Notification Sensor Product Manual

Features Industrial Long Range Wireless AC Current Detection Sensor One 0-100A AC Current Sensor 2 Mile Line-of-Sight Range with On-Board Antenna Superior LOS Range of up to 28 Miles with High-Gain Antennas Interface to Raspberry Pi, Microsoft® Azure®, AWS and More Example Software for Visual Studio and LabVIEW® Wireless Mesh Networking using DigiMesh® Open Communication Protocol for Easy Software Integration Small 3″ x 3″ Form Factor Wireless AC Current Detection Push Notification Power-Efficient Sleep Mode, Up to 10 Year Battery Life User Configurable Sleep duration Up to 500,000 Transmissions from 2 AA Batteries Includes Battery Level with Every Transmission Validates

Read More »

IoT Particulate Matter Sensor for Air Quality Monitoring Product Manual

OverviewFeaturesApplicationsDescriptionGetting StartedResources RequiredStepsTroubleshootingChanged/Unknown setting at sensor endChanged/Unknown setting at PC endModes of OperationMode Selection ProcessFrame Communication at Power upRun ModeAir Quality CO2 Temperature Humidity Particulate Matter SensorConfiguration ModeAppendix AConfiguration Commands1. Set Broadcast Transmission2. Set ID and Delay3. Set Destination Address4. Set Power5. Set PANID6. Set Retries7. Read Delay8. Read Power9. Read Retries10. Read Destination Address11. Read PANID12. Enable Encryption13. Disable Encryption14. Set Encryption Key15. Force Sensor CleanAppendix BFrame Checksum CalculationOverview Features Industrial Grade Sensor Mass concentration range 0-1000 μg/m^3 Mass concentration resolution 1 μg/m^3 Mass concentration size range PM1.0, PM2.5,PM4.0,PM10.0 Number concentration range 0 to 3000 1/cm^3 Number concentration size

Read More »

IoT Predictive Maintenance Sensor Manual

OverviewFeaturesApplicationsDescriptionGetting StartedResources RequiredStepsTroubleshootingChanged/Unknown setting at sensor endChanged/Unknown setting at PC endModes of OperationMode Selection ProcessFrame Communication at Power upRun ModeConfiguration ModeAppendix AConfiguration Commands1. Set Broadcast Transmission2. Set ID and Delay3. Set Destination Address4. Set Power5. Set PANID6. Set Retries7. Read Delay8. Read Power9. Read Retries10. Read Destination Address11. Read PANID12. Enable Encryption13. Disable Encryption14. Set Encryption KeyAppendix BFrame Checksum CalculationOverview Features Industrial Grade IoT Wireless Predictive Maintenance Sensor AC Current Range 0-100A RMS Measurement 3-axis Vibration Sensor with RMS, MAX and MIN Calculates g Vibration Data Across ±16g Range with Low Pass Filter Frequency Range (Bandwidth) up to 408 Hz Samples

Read More »